PESAN JURNAL KLIK SINI
....................................................................................................................................

Selasa, 17 Juli 2012

BEHAVIOUR OF HOLLOW COLUMNS CONFINED WITH FRP


Oleh : Yuliarti Kusumawardaningsih, Budi Sinaga Nandang
Civil Engineering Department, Faculty of Engineering, Semarang State University (UNNES) Campus UNNES Bld. E4, Sekaran, Gunungpati, Semarang 50229, Central Java, Indonesia.

Neda Fayaz Tousi
School of Civil, Mining and Environmental Engineering, University of Wollongong, NSW 2522, Australia.

Abstrak : Pelapisan kolom dengan komposit fiber reinforced polymer (FRP) telah diteliti selama beberapa tahun terakhir untuk menjawab masalah-masalah dalam peningkatan dan retrofit kolom-kolom beton bertulang; tetapi kebanyakan penelitian berkonsentrasi pada kolom-kolom solid. Tulisan ini mengungkapkan perbandingan perilaku dari FRP yang melapisi kolom beton bertulang berlubang yang dibebani oleh beban aksial terpusat. Sejumlah dua belas kolom terbuat dari beton mutu tinggi di uji. Enam kolom memiliki penampang bundar, dimana lima diantaranya adalah kolom berlubang. Kolom lainnya memiliki penampang persegi, dimana lima diantaranya adalah juga kolom berlubang. Enam kolom dari tiap konfigurasi tidak dilapisi oleh FRP berperan sebagai kolom control, sedangkan yang lainnya dilapisi dengan FRP. Dihasilkan bahwa pelapisan dengan FRP meningkatkan beban aksial dan kapasitas daktilitas kolom berlubang; kolom dengan lubang bundar memiliki perilaku yang lebih baik daripada kolom dengan lubang persegi.

Kata kunci : kolom beton, fiber reinforced polymers, beton mutu tinggi, penampang berlubang.

Abstract : Confining columns with fiber reinforced polymer (FRP) composites have been investigated in the last few decades to answer problems in upgrading and retrofitting reinforced concrete (RC) columns; however, most studies concentrate on solid columns. This paper investigates the comparative behaviour of FRP confined hollow RC columns subjected to axial concentric loading. A total of twelve RC columns made from high strength concrete (HSC) were tested. Six of the columns had a circular cross section and five of them were hollow columns. The remainder columns had a square cross section, similarly five of them were hollow columns. Six columns from each configuration were left unconfined as control specimens, while the others were confined with FRP. It was found that FRP confinement increased hollow RC columns’ axial load and ductility capacities; and hollow columns having circular holes had better performance compared to hollow columns having square holes.

Keywords : concrete columns, fiber reinforced polymers, high strength concrete, hollow sections.
order artikel


Bagikan konten ini melalui social media ...